1.4kW Single-Phase ATS / Metered PDU, 120V (8 5-15R), 2 5-15P, 100-127V Input, 2 12ft Cords, 1U Rack-Mount, TA. Single phase 15A 120V Auto Transfer Switch / ATS PDU. Enables redundant A/B power option for single-corded network devices. Separate primary & secondary inputs connect to any two compatible power sources. 1U horizontal rackmount; 2 NEMA 5-15P inputs; 8 NEMA 5-15R outlets. Two digit visual current meter reports equipment load in amps; Upgrade options available. Tripp Lite Metered ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED’s display primary or secondary power availability. 120V 15A Automatic Transfer Switch (ATS) / Metered PDU (Agency de-rated to 12A continuous). Provides a redundant A/B power option for non-redundant networking equipment with a single input power cord. Digital display continuously reports total output power consumption in amps. 1U horizontal rackmount form factor; 14.5 in. / 36.8 cm depth. 8 built-in NEMA 5-15R outlets. Set of two 12 ft. / 3.6m NEMA 5-15P input cables support connection to separate PRIMARY and SECONDARY power sources. ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable. ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series). Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Super-fast switchover between primary and secondary power sources occurs in 2-7 milliseconds. Built-in card slot supports optional SNMPWEBCARD or WEBCARDLX for permanent upgrade to a switched & monitored PDU system. Outlets are factory programmed for sequential turn-on at 250 millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction on startup. Front panel LEDs confirm power availability on both input lines. This item is used but in excellent condition and working order. Includes 2 power cords. The item “Tripplite PDUMH15AT Dual Input ATS/Metered 8 Outlet PDU 1U Rackmount” is in sale since Wednesday, April 18, 2018. This item is in the category “Computers/Tablets & Networking\Power Protection, Distribution\Power Distribution Units”. The seller is “firefighterchuck37″ and is located in Newport, Vermont. This item can be shipped to United States, Canada, United Kingdom, Denmark, Romania, Slovakia, Bulgaria, Czech republic, Finland, Hungary, Latvia, Lithuania, Malta, Estonia, Australia, Greece, Portugal, Cyprus, Slovenia, Japan, China, Sweden, South Korea, Indonesia, Taiwan, Belgium, France, Hong Kong, Ireland, Netherlands, Poland, Spain, Italy, Germany, Austria, Israel, New Zealand, Philippines, Singapore, Switzerland, Norway, Saudi arabia, Ukraine, United arab emirates, Qatar, Kuwait, Bahrain, Croatia, Malaysia.
  • Brand: Tripplite
  • Model: PDUMH15AT
  • Voltage Compatibility: 120V
  • Bundle Listing: No
  • Max. Input Current: 15A
  • MPN: pdumh15at