Server_Technology_STV_4501C_5_0kW_208V_L6_30P_PRO2_Switched_Master_PDU_C13_C19_01_bit
Server Technology STV-4501C 5.0kW 208V L6-30P PRO2 Switched Master PDU C13 C19
Server Technology STV-4501C 5.0kW 208V L6-30P PRO2 Switched Master PDU C13 C19
Server Technology STV-4501C 5.0kW 208V L6-30P PRO2 Switched Master PDU C13 C19
Server Technology STV-4501C 5.0kW 208V L6-30P PRO2 Switched Master PDU C13 C19
Server Technology STV-4501C 5.0kW 208V L6-30P PRO2 Switched Master PDU C13 C19

Server Technology STV-4501C 5.0kW 208V L6-30P PRO2 Switched Master PDU C13 C19
Point of Sale (POS). Power Backup and Management. Server Technology STV-4501C 5.0kW 208V L6-30P PRO2 Switched Master PDU C13 C19. Server Technology STV-4501C 5.0kW 1-Ph 208V L6-30P PRO2 Switched Master PDU 30-Outlet 24x C13 6x C19. Server Technology Model P/N: STV-4501C. Server Technology P/N: C2W30VA-2CBA2SD8/C. Condition: Clean, tested pull – Guaranteed 100% Working. This item is priced and packaged as pictured. Please note PDU color may be different. Most of the stock is red but we do have 1 black. No other accessories other than those pictured or mentioned in the listing will be included. Network monitoring: Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more. Hot swappable Network Card: Network access is ensured when power is lost to the Master unit with backup power provided by the primary link unit. Multi link expansion: Star Multi-Linking provides the ability to link up to four power circuits using one IP address. Primary link provides backup power to network card. Enviromental monitoring: Temperature/Humidity Monitoring. Master and Link units each support two external 10′ (3m) T/H probes. Input current monitor: Auto-flip current display. Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets. PIPS Per-Inlet Power Sensing: Meets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy. Branch current monitoring: PRO2 monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit. Branch circuit protection: This PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses. Outlet control: On Switched rack PDUs, cycle power to individual outlets or groups of outlets to reboot servers. Or, power off unused receptacles. High retention outlets: Receptacles have high retention and are compatible with P-Lock type power cords. Power pivot: The 90 degree rotatable power cord allows for standardized deployment at any facility no matter where power must be routed. Flexible mounting: Includes standard button mounts. Provisions for custom mounting brackets can be obtained by contactacting Server Technology. The Server Technology PRO2 Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Switched “Master” PDU can be connected to as many as three (with optional module) PRO2 Switched “Link” PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration. Input Current Rated (A). Input Power Capacity (kW). (24) x IEC 60320/C13. (6) x IEC 60320/C19. Dimensions: 69.0in tall x 2.2in wide x 2.3in deep [1753mm x 56mm x 59mm]. North American : cTUVus Mark to UL 60950-1:2007 R10.14 CAN/CSA-C22.2 No. 60950-1-07+A1:2011+A2:2014 FCC Part 15 Subpart B Sections 15.107 and 15.109, Class A. Input Measurement Accuracy: LED Current = ± 10% at 0.1 amp (0.3 – 9.9 amps) and 1 amp (> 9.9 amps) resolution GUI Current = ± 1% at 0.01 amp resolution (above 0.25 amp) Voltage = ± 1% at 0.1 volt resolution (nominal ± 10%) Active Power = ± 1% at 1 watt resolution Apparent Power = ± 1% at 1 volt-amp resolution Power Factor = ± 3% at 0.01 resolution Crest Factor = ± 10% at 0.1 resolution Energy = ± 1% at 0.1 kilowatt-hour resolution Branch Measurement Accuracy Current = ± 3% at 0.01 amp resolution (above 0.5 amp). All sales are final. Storage solutions, power and testing equipment. We offer lowest prices on hard to find parts! Asset recovery and recycling services. Open: Mo-Fri 10:00am – 07:00pm CST. At the bottom of the listing there is a “Ask a question” link. If it doesn’t work for you, our contact information is published on the world wide web. Please use you imagination and investigative skills. The truth is out there! The item “Server Technology STV-4501C 5.0kW 208V L6-30P PRO2 Switched Master PDU C13 C19″ is in sale since Monday, February 17, 2020. This item is in the category “Computers/Tablets & Networking\Power Protection, Distribution\Power Distribution Units”. The seller is “techy_parts” and is located in Burnsville, Minnesota. This item can be shipped worldwide.
  • Brand: SERVER TECHNOLOGY
  • Model: STV-4501C
  • MPN: C2W30VA-2CBA2SD8/C
  • Outlets: 24x C13, 6x C19
  • Voltage Compatibility: 208V
  • Max. Input Current: 30 A
  • Custom Bundle: No
  • Modified Item: No

Server Technology STV-4501C 5.0kW 208V L6-30P PRO2 Switched Master PDU C13 C19