APC Rack PDU 9000 Switched APDU9953 – Power distribution unit (rack-mountable) – AC 230 V – 7400 VA – Ethernet 10/100/1000 – input: IEC 60309 32A – output connectors: 24 (3 x IEC 60320 C19, 21 x IEC 60320 C13) – 0U – 3.05 m cord – black :: APDU9953 Ente. Images for illustration purposes only. NetShelter Switched Rack PDUs & Benefits Manageability 1% Metering Accuracy Providing the same level of accuracy as a utility company meter by adhering to IEC 62053-21 class 1, 1% metering accuracy provides peace of mind to use these PDUs to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Available on 9000 series PDUs. Gigabit Ethernet Connectivity 9000 series PDUs provide Gigabit Ethernet to enhance and standardize network connectivity across all assets in the data center. All other models provide 10/100 ethernet connectivity. Network Port Sharing Connect and manage multiple PDUs from one IP address to simplify and speed deployment while saving the cost required in having a dedicated network connection for each PDU. Manage up to 32 PDUs with 9000 series and up to 4 PDUs with 8000 series. Multi-tier user access Supports up to four access levels – Administrator, Device User, Read-Only User and Network-only User – with user name and password requirements. Outlet Level Grouping Outlet power sequencing can be configured to group any combination of outlets to power up or down together providing flexibility. EcoStruxure IT Ready Seamless integration of one or many PDUs including alerts and control with EcoStruxure IT. Allows IT and data center professionals to monitor and manage all of their critical IT infrastructure on-premise, in the cloud, and at the edge from anywhere. Enhanced Cybersecurity 9000 series PDUs include APC Network Management card with security features including secured interfaces and a modified password policy providing peace of mind. Network Management Capabilities Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements. Alarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. Adaptability Rack-Mountable Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most – in the racks near the equipment. Single input power source Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Wide range of input and output connections Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 17.3kW using a single branch whip. Agility Wireless Connectivity Compatible with the optional APC USB WiFi Device for cableless connectivity over WiFi that speeds deployment and simplifies moves, adds, and changes (9000 Series PDUs only – expected to be available on units manufactured after March 2021). Flash Upgradeable Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only) Availability 60C Operating Temperature Select 9000 series PDUs provide the ability to operate in a maximum ambient air temperature of 60C (140F) at full load ensuring reliability and availability even in today’s high density deployments. Other models allow up to 45C (113F). Hydraulic Magnetic Circuit Breakers Provide increased availability by maintaining trip current over a wide temperature range. C13/C15 and C19/C21 Hybrid Outlets Available on select 9000 series PDUs only, Industry 1st hybrid outlets allow 60C operating temperature at full load, are fully compatible with standard C14 and C20 power cords, and are future proofed for implementation of higher temperature rated devices requiring C16 and C21 power cords. High Retention Outlets With no special power cords required, high retention outlets provide up to twice the holding force to reduce risk of accidental disconnect on 9000 series PDUs. Field-replaceable NMC Integrated Network Management Card/Display Module can be replaced in the field to minimize downtime disruption in the unlikely event of a failure. Includes: Installation guide, Rack mounting brackets, Safety guide, Serial configuration cable. With Industry leading reliability, manageability, and security, APC Switched Rack PDU’s provide advanced load management plus on/off outlet level power cycling and sequencing control. The button which is pressed to switch the device on or off. The spase that device fill in rack. Characteristics of the device. A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted “power strips” to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP. EAC, EN 55022 class A, EN 55024, EN 61000-3-2, EN 61000-3-3, RCM, VDE. 0 – 15240 m. 0 – 3048 m. Operating relative humidity (H-H). Storage relative humidity (H-H). The minimum and maximum temperatures at which the product can be safely stored. The minimum and maximum temperatures at which the product can be safely operated. The distance from the top to the bottom of the packaging. The distance from the front to the back of the packaging. The distance from one side of the packaging to the other. Weight of the packaged product. The type of outlet for AC electricity. C13 coupler, C19 coupler. A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. The number of sockets in the device where AC electrical power can be connected. 24 AC outlet(s). The maximum power that can be put into or produced by the device. The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge. 50 – 60 Hz. 200, 208, 230, 220-240 V. Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. The measurement of the product from head to foot or from base to top. The distance from the front to the back of something. The measurement or extent of something from side to side.
APC Rack PDU 9000 Switched APDU9953 – Power distribution unit (rack-mountable) – AC 230 V – 7400 VA – Ethernet 10/100/1000 – input: IEC 60309 32A – output connectors: 24 (3 x IEC 60320 C19, 21 x IEC 60320 C13) – 0U – 3.05 m cord – black :: APDU9953 Ente. Images for illustration purposes only. NetShelter Switched Rack PDUs & Benefits Manageability 1% Metering Accuracy Providing the same level of accuracy as a utility company meter by adhering to IEC 62053-21 class 1, 1% metering accuracy provides peace of mind to use these PDUs to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Available on 9000 series PDUs. Gigabit Ethernet Connectivity 9000 series PDUs provide Gigabit Ethernet to enhance and standardize network connectivity across all assets in the data center. All other models provide 10/100 ethernet connectivity. Network Port Sharing Connect and manage multiple PDUs from one IP address to simplify and speed deployment while saving the cost required in having a dedicated network connection for each PDU. Manage up to 32 PDUs with 9000 series and up to 4 PDUs with 8000 series. Multi-tier user access Supports up to four access levels – Administrator, Device User, Read-Only User and Network-only User – with user name and password requirements. Outlet Level Grouping Outlet power sequencing can be configured to group any combination of outlets to power up or down together providing flexibility. EcoStruxure IT Ready Seamless integration of one or many PDUs including alerts and control with EcoStruxure IT. Allows IT and data center professionals to monitor and manage all of their critical IT infrastructure on-premise, in the cloud, and at the edge from anywhere. Enhanced Cybersecurity 9000 series PDUs include APC Network Management card with security features including secured interfaces and a modified password policy providing peace of mind. Network Management Capabilities Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements. Alarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. Adaptability Rack-Mountable Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most – in the racks near the equipment. Single input power source Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Wide range of input and output connections Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 17.3kW using a single branch whip. Agility Wireless Connectivity Compatible with the optional APC USB WiFi Device for cableless connectivity over WiFi that speeds deployment and simplifies moves, adds, and changes (9000 Series PDUs only – expected to be available on units manufactured after March 2021). Flash Upgradeable Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only) Availability 60C Operating Temperature Select 9000 series PDUs provide the ability to operate in a maximum ambient air temperature of 60C (140F) at full load ensuring reliability and availability even in today’s high density deployments. Other models allow up to 45C (113F). Hydraulic Magnetic Circuit Breakers Provide increased availability by maintaining trip current over a wide temperature range. C13/C15 and C19/C21 Hybrid Outlets Available on select 9000 series PDUs only, Industry 1st hybrid outlets allow 60C operating temperature at full load, are fully compatible with standard C14 and C20 power cords, and are future proofed for implementation of higher temperature rated devices requiring C16 and C21 power cords. High Retention Outlets With no special power cords required, high retention outlets provide up to twice the holding force to reduce risk of accidental disconnect on 9000 series PDUs. Field-replaceable NMC Integrated Network Management Card/Display Module can be replaced in the field to minimize downtime disruption in the unlikely event of a failure. Includes: Installation guide, Rack mounting brackets, Safety guide, Serial configuration cable. With Industry leading reliability, manageability, and security, APC Switched Rack PDU’s provide advanced load management plus on/off outlet level power cycling and sequencing control. The button which is pressed to switch the device on or off. The spase that device fill in rack. Characteristics of the device. A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted “power strips” to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP. EAC, EN 55022 class A, EN 55024, EN 61000-3-2, EN 61000-3-3, RCM, VDE. 0 – 15240 m. 0 – 3048 m. Operating relative humidity (H-H). Storage relative humidity (H-H). The minimum and maximum temperatures at which the product can be safely stored. The minimum and maximum temperatures at which the product can be safely operated. The distance from the top to the bottom of the packaging. The distance from the front to the back of the packaging. The distance from one side of the packaging to the other. Weight of the packaged product. The type of outlet for AC electricity. C13 coupler, C19 coupler. A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. The number of sockets in the device where AC electrical power can be connected. 24 AC outlet(s). The maximum power that can be put into or produced by the device. The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge. 50 – 60 Hz. 200, 208, 230, 220-240 V. Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. The measurement of the product from head to foot or from base to top. The distance from the front to the back of something. The measurement or extent of something from side to side.