Gude_8001_Pdu_01_adc
Gude 8001 Pdu
Gude 8001 Pdu
Gude 8001 Pdu

Gude 8001 Pdu
5-fold switched and outlet-metered PDU. Expert Power Control 8001-1 for more operational security and energy efficiency in 19-inch installations. Demonstrably fewer and shorter outages. Of your critical IT and AV infrastructure. Detect AV and IT problems earlier. Through proactive power monitoring per port and environment monitoring. Measurably increased energy efficiency (Green IT and AV). Electricity cost and CO2 savings through controlled switching off of devices. Quickly and easily integrate anywhere with API interface: REST API, HTTPS, SNMP, Telnet and MQTT. Fix AV and IT problems quickly and effectively. Remote reboot or with the self-healing function (automatic restart) thanks to integrated watchdogs. Event and schedule controlled switching. Precise current metering per power outlet of up to 9 units and residual current. Connector for plug-and-play sensors for real-time monitoring. Fast and easy installation on support rails with hat profile. NTP function can be activated. More flexibility through Radius, Modbus TCP and MQTT 3.1.1 support. Each power port can be switched via HTTP(S), SNMP, ModbusTCP or command line interface via Telnet, SSH, MQTT and serial interface. Programmable on/off sequences for remote reboots. Power ports can be switched when preset sensor thresholds are exceeded. Self-healing function thanks to 5-channel watchdog: Each power port can be assigned its own. (ICMP/TCP), which initiates an automatic restart if necessary. Switching state and switch-on delay up to 9999 seconds (166 minutes) individually adjustable for each output port after power failure. Current peaks due to increased inrush currents are automatically prevented by sequential switch-on with a latency of 1 second. Power consumption metering (kwH) per power outlet with 2 energy counters: one counter counts consistently, the other counter is resettable. Metering of current (A), voltage (V), phase angle, power factor, frequency (Hz), active power (W), apparent power (VA) and reactive power (VAr). Connector for combined plug-and-play sensors (temperature, humidity and air pressure) to prevent physical hazards that often occur, such as overheating and increased humidity or air pressure. Encrypted e-mails (SSL, STARTTLS). Access protection by IP access control. Encrypted communication through SSL (TLS 1.1, 1.2, 1.3) and SSH. Beeper for audible alarm when sensor limits are exceeded. Easy-to-read LED display for displaying total current, IP address and sensor values. Firmware update via Ethernet during operation (no restart required). Dynamic assignment of an IP address via DHCP or manual assignment of static IP address. Rapid commissioning thanks to free and reliable drivers from GUDE’s technology partners. Manual available on Gude’s official site.
Gude 8001 Pdu