TRIPP_LITE_PDU_3XVSR6L2230B_PDU_3_Phase_Switched_240V_17_3kW_C13_C19_L22_30P_01_lhk
TRIPP LITE PDU 3XVSR6L2230B PDU 3-Phase Switched 240V 17.3kW C13 C19 L22-30P
TRIPP LITE PDU 3XVSR6L2230B PDU 3-Phase Switched 240V 17.3kW C13 C19 L22-30P
TRIPP LITE PDU 3XVSR6L2230B PDU 3-Phase Switched 240V 17.3kW C13 C19 L22-30P
TRIPP LITE PDU 3XVSR6L2230B PDU 3-Phase Switched 240V 17.3kW C13 C19 L22-30P
TRIPP LITE PDU 3XVSR6L2230B PDU 3-Phase Switched 240V 17.3kW C13 C19 L22-30P
TRIPP LITE PDU 3XVSR6L2230B PDU 3-Phase Switched 240V 17.3kW C13 C19 L22-30P
TRIPP LITE PDU 3XVSR6L2230B PDU 3-Phase Switched 240V 17.3kW C13 C19 L22-30P
TRIPP LITE PDU 3XVSR6L2230B PDU 3-Phase Switched 240V 17.3kW C13 C19 L22-30P
TRIPP LITE PDU 3XVSR6L2230B PDU 3-Phase Switched 240V 17.3kW C13 C19 L22-30P
TRIPP LITE PDU 3XVSR6L2230B PDU 3-Phase Switched 240V 17.3kW C13 C19 L22-30P
TRIPP LITE PDU 3XVSR6L2230B PDU 3-Phase Switched 240V 17.3kW C13 C19 L22-30P
TRIPP LITE PDU 3XVSR6L2230B PDU 3-Phase Switched 240V 17.3kW C13 C19 L22-30P

TRIPP LITE PDU 3XVSR6L2230B PDU 3-Phase Switched 240V 17.3kW C13 C19 L22-30P
Switched 17.3kW 3-Phase 415V input, 240V output PDU. Reports voltage & load per-outlet or per phase via ethernet interface. 1% billing-grade accuracy; Digital display reports detailed status information. 70in / 1778mm 0U vertical format; Toolless button-mount installation. 24 C13 & 6 C19 single phase outlets; Plug-lock cable retention inserts. NEMA L22-30P 3 phase input; 6ft 1.8m line cord. Tripp Lite 3 phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption per-phase or per-receptacle. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps per-phase or per-receptacle can be displayed locally via visual meter or remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip. Highly accurate current metering offers +/-1% billing-grade current monitoring and recording ability for each output phase, breakered load bank and individual outlet. 17.3kW Switched 415V input 240V output PDU with built-in web/network interface. Attached NEMA L22-30P (3P+N+E) 415V 3 phase input; 6ft. / 1.8m cord. 0U, 70 inch / 178cm vertical form factor. 30 switched 240V outlets (24 C13, 6 C19) in 6 separately breakered 20A single phase load banks. Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis. Enables reboot of locked equipment, custom power-on/power-off sequences, load shedding of optional loads and disabling unused outlets. Network interface provides PDU control and data regarding input voltage and load levels per-outlet, per-breaker and per-phase. Built-in local digital display and remote web/network interface reports detailed voltage, amperage and kilowatt output values per outlet, per breaker and per phase with additional reporting options for power unbalance percentage, IP address and sensor based temperature and humidity data (requires ENVIROSENSE sensor). In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors. Local display supports electronic 180 degree display rotation for overhead or under-floor input cable orientation. Supports user-specified alarm notification thresholds. Real-time clock backup maintains the time of day and date even if the PDU is unpowered. Firmware upgrade ability supports future product enhancements. Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTPP, DHCP, BootP, NTP protocols. Fully compatible with FREE PowerAlert Network Management System / NMS Software. Included set of Plug-lock inserts keep C14 and C20 power cords solidly connected to PDU outlets. Toolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for other mounting applications (set of 2 9mm buttons pre-installed, 2 9mm and 4 6mm spare buttons included). 17.3kW (415/240V), 16.6kW (400/230V), 15.8kW (380/220V) total capacity; 24A max per output phase (L1, L2, L3); 20A max per breakered outlet bank; 16A max per C19 outlet; 12A max per C13 outlet. 50 / 60 Hz. (24) C13; (6) C19. 6 20A circuit breakers, one per output load bank. 30A 415/240V with NEMA L22-30R outlet. Input Cord Length ft. USER INTERFACE, ALERTS & CONTROLS. Reports input current per phase (L1, L2, L3), plus output current for each output load bank (B1-B6) and individual output receptacle (1-30); Outlets are color-coded and labeled for phase and load bank identification; L1-N feeds black outlets (B1, B4); L2-N feeds dark-gray outlets (B2, B5); L3-N feeds light-gray outlets (B3, B6). Front Panel LCD Display. Large digital display reports Amperage, Kilowatts, Voltage, Unbalance percentage, Temperature and Humidity information (requires ENIVIROSENSE option); Small digital display provides detail on the measurement the large display is reporting: Input-phase (L#), Load bank (B#), Sensor (S#), Outlet (##), Load unbalance % (UB), Output power (OP). Set of 6 LEDs identify the value displayed on the large digital display: Amperage (A), Kilowatts (kW), Voltage (V), Unbalance percentage (%UB), Temperature (T), Humidity (%RH); One additional LED for each output receptacle offers power availability information: GREEN Power ON, load bank capacity. 80%, RED (Power OFF/undervoltage), RED FLASHING (Power OFF/breaker trip). Set of UP/DOWN arrow buttons scroll through available Input, Bank, Power, Load balance and Sensor options; Additional MODE button advances the LEDs to view the next measurement. 75.87 x 9.65 x 6.89. Unit Dimensions hwd / in. 70 x 2.17 x 2.52. Vertical rackmount installation supported with included mounting brackets; supports toolless mounting in button-mount compatible racks. 32 to 122F (0C to 50C). 5 to 140F (-15 to 60C). 5 to 95% non-condensing. TAA Compliant version available – Order Tripp Lite PDU3XEVSR6L230B. Tested to UL60950-1 (USA), CSA22.2 (Canada), NOM (Mexico), FCC Class A (Emissions), RoHS (Hazardous Substances). The item “TRIPP LITE PDU 3XVSR6L2230B PDU 3-Phase Switched 240V 17.3kW C13 C19 L22-30P” is in sale since Thursday, December 27, 2018. This item is in the category “Computers/Tablets & Networking\Power Protection, Distribution\Power Distribution Units”. The seller is “discount_materials” and is located in Nashville, Tennessee. This item can be shipped to United States, Canada, United Kingdom, Denmark, Romania, Slovakia, Bulgaria, Czech republic, Finland, Hungary, Latvia, Lithuania, Malta, Estonia, Australia, Greece, Portugal, Cyprus, Slovenia, Japan, China, Sweden, South Korea, Indonesia, Taiwan, South africa, Belgium, France, Hong Kong, Ireland, Netherlands, Poland, Spain, Italy, Germany, Austria, Bahamas, Israel, Mexico, New Zealand, Philippines, Singapore, Switzerland, Norway, Saudi arabia, Ukraine, United arab emirates, Qatar, Kuwait, Bahrain, Croatia, Brazil, Chile, Colombia, Costa rica, Panama, Trinidad and tobago, Guatemala, Honduras, Jamaica, Montserrat, Turks and caicos islands, Bolivia, Ecuador, Egypt, Guadeloupe, Cayman islands, Luxembourg, Maldives, Peru, Paraguay, Viet nam, Uruguay, Dominican republic, El salvador, Antigua and barbuda, Aruba, Belize, Dominica, Grenada, Saint kitts and nevis, Saint lucia, Barbados, Bangladesh, Bermuda, Brunei darussalam, French guiana, Guernsey, Gibraltar, Iceland, Jersey, Jordan, Cambodia, Liechtenstein, Sri lanka, Monaco, Macao, Martinique, Nicaragua, Oman, Pakistan, Reunion.
  • Brand: Tripp Lite
  • Cable Length: 6 ft
  • Model: 3-Phase Switched PDU
  • Voltage Compatibility: 240 V
  • MPN: PDU3XVSR6L2230B

TRIPP LITE PDU 3XVSR6L2230B PDU 3-Phase Switched 240V 17.3kW C13 C19 L22-30P