APC power distribution unit (PDU) 24 AC outlets 0U 24-Outlets Black AP8941 Network Management Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements. Remote Individual Outlet Control Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment). Alarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability Local Current Monitoring Display The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only) Power Delays Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly. Load indicator LED Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits. Flash Upgradeable Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only) Integrates with InfraStruXure Central An IT-ready, scalable monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network. APC power distribution unit (PDU) 24 AC outlets 0U 24-Outlets Black AP8941. APC power distribution unit (PDU) 24 AC outlets 0U 24-Outlets Black AP8941 Network Management. Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Remote Individual Outlet Control. Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment). Define alarm thresholds in order to avoid overloaded circuits. Please see SKU specifications for availability. Local Current Monitoring Display. The aggregate current draw per power distribution unit is displayed on the unit via a digital display. (Available on designated SKUs only). Allows users to configure the sequence in which power is turned on or off for each outlet. Indicates overload and warning conditions based on the user-defined alarm thresholds. Quickly and easily upgrade firmware via network download for future product enhancements. (Note: Networked units only). Integrates with InfraStruXure Central. An IT-ready, scalable monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network. AC outlets quantity: 24 AC outlet(s). Power plug: NEMA L6-30P. Cable length: 3.05 m. Certification: CUL, FCC Part 15 A, ICES-003, PSE, UL, VCCI A. Nominal input voltage: 200-230 V. AC input frequency: 50 – 60 Hz. Maximum current: 30 A. Nominal output voltage: 208 V. Maximum total current draw per phase: 30 A. Power protection features: Overload. Dimensions (WxDxH): 56 x 46 x 1829 mm. Weight: 7.64 kg. Package dimensions (WxDxH): 165 x 124 x 2040 mm. Package weight: 10 kg. Operating temperature (T-T): -5 – 45 °C. Storage temperature (T-T): -25 – 65 °C. Operating relative humidity (H-H): 5 – 95%. Storage relative humidity (H-H): 5 – 95%. Operating altitude: 0 – 3000 m. Non-operating altitude: 0 – 15000 m. We post all orders within 24 working-hours Monday to Friday. All items must be complete including original packaging, accessories and literature. Based on the condition of the product. You order the wrong item, not a problem, don? T open it send it back we will swap it for you. If unsure please talk to us first. You may return any new. We are a large. UK retailer that frequently clears lots of new, aged, excess and End of Life (EOL) inventory. Get images that make Supersized seem small. Showcase your items with Auctiva’s. Track Page Views With. Auctiva’s FREE Counter.
APC power distribution unit (PDU) 24 AC outlets 0U 24-Outlets Black AP8941 Network Management Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements. Remote Individual Outlet Control Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment). Alarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability Local Current Monitoring Display The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only) Power Delays Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly. Load indicator LED Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits. Flash Upgradeable Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only) Integrates with InfraStruXure Central An IT-ready, scalable monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network. APC power distribution unit (PDU) 24 AC outlets 0U 24-Outlets Black AP8941. APC power distribution unit (PDU) 24 AC outlets 0U 24-Outlets Black AP8941 Network Management. Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Remote Individual Outlet Control. Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment). Define alarm thresholds in order to avoid overloaded circuits. Please see SKU specifications for availability. Local Current Monitoring Display. The aggregate current draw per power distribution unit is displayed on the unit via a digital display. (Available on designated SKUs only). Allows users to configure the sequence in which power is turned on or off for each outlet. Indicates overload and warning conditions based on the user-defined alarm thresholds. Quickly and easily upgrade firmware via network download for future product enhancements. (Note: Networked units only). Integrates with InfraStruXure Central. An IT-ready, scalable monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network. AC outlets quantity: 24 AC outlet(s). Power plug: NEMA L6-30P. Cable length: 3.05 m. Certification: CUL, FCC Part 15 A, ICES-003, PSE, UL, VCCI A. Nominal input voltage: 200-230 V. AC input frequency: 50 – 60 Hz. Maximum current: 30 A. Nominal output voltage: 208 V. Maximum total current draw per phase: 30 A. Power protection features: Overload. Dimensions (WxDxH): 56 x 46 x 1829 mm. Weight: 7.64 kg. Package dimensions (WxDxH): 165 x 124 x 2040 mm. Package weight: 10 kg. Operating temperature (T-T): -5 – 45 °C. Storage temperature (T-T): -25 – 65 °C. Operating relative humidity (H-H): 5 – 95%. Storage relative humidity (H-H): 5 – 95%. Operating altitude: 0 – 3000 m. Non-operating altitude: 0 – 15000 m. We post all orders within 24 working-hours Monday to Friday. All items must be complete including original packaging, accessories and literature. Based on the condition of the product. You order the wrong item, not a problem, don? T open it send it back we will swap it for you. If unsure please talk to us first. You may return any new. We are a large. UK retailer that frequently clears lots of new, aged, excess and End of Life (EOL) inventory. Get images that make Supersized seem small. Showcase your items with Auctiva’s. Track Page Views With. Auctiva’s FREE Counter.