Server_Technology_Inc_switch_cabinet_distribution_unit_CWG_16HEK454_01_jbde
Server Technology Inc, switch cabinet distribution unit (CWG-16HEK454)
Server Technology Inc, switch cabinet distribution unit (CWG-16HEK454)
Server Technology Inc, switch cabinet distribution unit (CWG-16HEK454)
Server Technology Inc, switch cabinet distribution unit (CWG-16HEK454)
Server Technology Inc, switch cabinet distribution unit (CWG-16HEK454)
Server Technology Inc, switch cabinet distribution unit (CWG-16HEK454)
Server Technology Inc, switch cabinet distribution unit (CWG-16HEK454)

Server Technology Inc, switch cabinet distribution unit (CWG-16HEK454)
Server Technology Inc, switch cabinet distribution unit (CWG-16HEK454). New and unused but unboxed, has been PAT tested. (Taken from Server Technology’s website). The Server Technology® Switched POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® and POPS® technology provides accurate measurement of current (billing-grade), voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The Switched POPS “Primary” PDU can be connected to a Switched POPS “Link” PDU to extend the network access to the redundant or secondary power feed. IEC 230V/32A 2P+PE 6Hr. Input Current Rated (A). Input Power Capacity (kW). (16) x IEC 60320/C13. Dimensions: 3.5in tall x 17.2in wide x 7.1in deep [89mm x 437mm x 181mm]. EN IEC 62368-1 (TUVR certified, T-mark). Regional, national and harmonized differences (IECEE CB scheme) EMC. EN 55032 / CISPR 32. EN 55035 / CISPR 35. EN 61000-3-2 / IEC 61000-3-2. EN 61000-3-3 / IEC 61000-3-3. 2014/35/EU (Low Voltage Directive). Input Measurement Accuracy: LED Current = ± 10% at 0.1 amp (0.3 – 9.9 amps) and 1 amp (> 9.9 amps) resolution GUI Current = ± 1% at 0.01 amp resolution (above 0.25 amp) Voltage = ± 1% at 0.1 volt resolution (nominal ± 10%) Active Power = ± 1% at 1 watt resolution Apparent Power = ± 1% at 1 volt-amp resolution Power Factor = ± 3% at 0.01 resolution Crest Factor = ± 10% at 0.1 resolution Energy = ± 1% at 0.1 kilowatt-hour resolution Output Measurement Accuracy GUI Current = ± 1% at 0.01 amp resolution (above 0.15 amp) Voltage = ± 1% at 0.1 volt resolution (nominal ± 10%) Active Power = ± 1% at 1 watt resolution Apparent Power = ± 1% at 1 volt-amp resolution Power Factor = ± 3% at 0.01 resolution Crest Factor = ± 10% at 0.1 resolution Energy = ± 1% at 1 watt-hour resolution. Any questions please feel free to ask and please check out our other items.
Server Technology Inc, switch cabinet distribution unit (CWG-16HEK454)