AP8481_APC_Metered_by_Outlet_Rack_PDU_2G_Power_distribution_unit_rack_mountab_01_isw
AP8481 APC Metered-by-Outlet Rack PDU 2G Power distribution unit rack-mountab
AP8481 APC Metered-by-Outlet Rack PDU 2G Power distribution unit rack-mountab
AP8481 APC Metered-by-Outlet Rack PDU 2G Power distribution unit rack-mountab

AP8481 APC Metered-by-Outlet Rack PDU 2G Power distribution unit rack-mountab
Inkjet and Photo Printers. DVD & Home Cinema. CD & DVD Drives. Tape and DAT Drives. Other Drives and Storage. AP8481 APC Metered-by-Outlet Rack PDU 2G – Power distribution unit (rack-mountable) – AC 400 V – 3-phase – RS-232 – output connectors: 24 – 0U – black – for P/N: SMX1000C, SMX1500RM2UC, SMX1500RM2UCNC, SMX750C, SMX750CNC, SRT5KRMXLW-TW :: AP8481 Enterpr. Images for illustration purposes only. Metering-by-Outlet capability Individual outlet level power metering provides a more granular view of the power distributed to equipment within the enclosure. It also provides the ability to analyze component power trends and perform capacity planning. Network Management Capabilities Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements. Alarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability Local Current Monitoring Display The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only) Load indicator LED Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits. (Note: Only available with units with local current monitoring feature) Flash Upgradeable Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only) Integrates with StruxureWare Data Center Expert An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network Single input power source Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. The spase that device fill in rack. A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted “power strips” to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP. EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Class A, ICES-003, UL, VDE, REACH. How long the cable is. 0 – 15000 m. Operating relative humidity (H-H). Storage relative humidity (H-H). The minimum and maximum temperatures at which the product can be safely stored. The minimum and maximum temperatures at which the product can be safely operated. Dimensions of the packaged product (Width x Depth x Height). 163 x 117 x 2037 mm. Weight of the packaged product. 21 x C13 & 3 x C19. The type of connection /port for the input(s) into this device e. IEC 309 16A 3P+N+PE, IEC 309 20A 3P+N+E. The type of outlet for AC electricity. C13 coupler, C19 coupler. A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. The number of sockets in the device where AC electrical power can be connected. 24 AC outlet(s). The maximum power that can be put into or produced by the device. Maximum total current draw per phase. Maximum input current per phase. 50 – 60 Hz. Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Dimensions of the product (Width x Depth x Height). 56 x 51 x 1829 mm. This item is in the category “Computers/Tablets & Networking\Power Protection, Distribution\Power Distribution Units”. The seller is “morefrom” and is located in this country: GB. This item can be shipped to United Kingdom.
  • Type: Power Distribution Units (PDUs)
  • Model: 400
  • Colour: Black
  • Brand: APC
  • Compatible Brand: APC
  • MPN: AP8481
  • EAN: 0731304317609

AP8481 APC Metered-by-Outlet Rack PDU 2G Power distribution unit rack-mountab